How centrifugal compression differs

Scroll and reciprocating compressors trap a volume of gas and reduce it. A centrifugal compressor accelerates the gas in the impeller and converts that velocity into pressure in the diffuser. There is no general efficiency ranking between the types. Compare complete machines at your duty: capacity, turndown, operating map and service capability.

Part load and temperature lift

EMT compressors run on a variable-speed drive that follows demand. Check four limits together: minimum stable load, permitted pressure ratio, the source temperature range and the sequencing of several units. A single nominal COP says little about a year of operation; ask for performance at the part-load operating cases you expect.

Depending on the model, the EMT heating points in the table below use water at 12 → 7 °C on the cold side and 47 → 53 °C or 57 → 63 °C on the hot side. COP values not yet confirmed are marked ‘Withheld pending confirmation’.

Check the model documentation

Compressor count and refrigerant-circuit count vary across the range and are different things. ECO and FT name documented model variants; the letters do not tell you the circuit layout, the redundancy or whether performance is interchangeable. Check the exact model against its datasheet and hydraulic drawing.

EMT machines use shell-and-tube heat exchangers with flooded evaporation. ‘Flooded’ describes the refrigerant side; it does not mean any process fluid can be connected. Check water quality, freeze protection, cleaning access and pressure drop for the selected arrangement.

Models and documented rating conditions

Rating points as printed in each datasheet. They describe one operating case each, not the operating envelope. Where a datasheet omits the electrical boundary, load or speed, the row says so.

Temperatures are fluid inlet → outlet in °C, capacity in kW. Compare rows only at the same temperatures and boundary.
Model / refrigerantSource inlet → outletHeated water inlet → outletDeclared dutyThermal capacity / COPDocument / boundary
EMT 1230-1-4-ECO
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
265 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1230-1-7-ECO
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
265 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1285-1-4-ECO
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
347 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1285-1-7-ECO
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
347 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1310-1-4-ECO
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
379 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1310-1-7-ECO
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
379 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1380-1-4-ECO
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
476 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1380-1-7-ECO
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
476 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1490-1-4-ECO
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
589 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 1490-1-7-ECO
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
589 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2230-1-4-FT
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
530 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2230-1-7-FT
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
530 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2230-2-4-ECO
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
530 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2230-2-7-ECO
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
530 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2285-1-4-FT
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
694 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2285-1-7-FT
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
694 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2285-2-4-ECO
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
694 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2285-2-7-ECO
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
694 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2310-1-4-FT
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
758 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2310-1-7-FT
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
758 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2310-2-4-ECO
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
758 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2310-2-7-ECO
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
758 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2380-1-4-FT
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
951 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2380-1-7-FT
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
951 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2380-2-4-ECO
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
951 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2380-2-7-ECO
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
951 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2490-1-4-FT
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,178 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2490-1-7-FT
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,178 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2490-2-4-ECO
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,178 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 2490-2-7-ECO
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,178 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 3285-1-4-FT
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,041 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 3285-1-7-FT
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,041 kW
COP: Withheld pending confirmation
Datasheet V1.8 · 2025-12-04 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4230-1-4-FT
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,060 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4230-1-7-FT
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,060 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4285-1-4-FT
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,388 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4285-1-7-FT
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,388 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4310-1-4-FT
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,516 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4310-1-7-FT
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,516 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4380-1-4-FT
R1234ze
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,902 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4380-1-7-FT
R515B
water
12 → 7 °C
water
57 → 63 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
1,902 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4490-1-4-FT
R1234ze
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
2,356 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated
EMT 4490-1-7-FT
R515B
water
12 → 7 °C
water
47 → 53 °C
Heating
Speed: Not stated
Load: Not stated
No subcooler / standard configuration
2,356 kW
COP: Withheld pending confirmation
Datasheet V1.7 · 2024-12-23 · EN · p. 2
Electrical input: Not stated (Not stated)
COP scope: Not stated
Test standard: Not stated

Related