EMB

2295-1-4

Product Family:
EMB
Certification:
CE
Refrigerant Type:
R1234ze
Safety Class:
A2L
Capacity Control:
2-Stepped

Application

Nominal Heating Capacity:
114 kW
Nominal Cooling Capacity:
144 kW
Nominal COP Heating:
2.79
Nominal COP Cooling:
4.18
Condenser Outlet Temp.:
65 °C
Evaporator Inlet Temp.:
-4 °C
Lowest Evaporator Temp. To Reach Highest Condenser Temp.:
0 °C
Highest Evaporator Outlet Temp.:
20 °C

Dimensions

Length:
1970 mm
Width:
860 mm
Height:
1895 mm
Weight:
1450 kg

Technical Features

Compressor Type:
Scroll
Energy Source:
Ground, Waste heat, Water
Special Features:
Internal pumps
GWP:
1.37

The Energy Machines™ EMB models are designed for space heating, warm tap water production, and comfort cooling. They contain either one or two refrigerant circuits with two compressors in each.

The EMB models operate with either one or two heat source circuits containing brine. These circuits have an integrated circulation pump and switch between the production of hot tap water and the production of heat.

The EMB comes as a completely reversible heat pump in one unit.

Documentation

Check an operating point

Indicative — engineering review
Cold side (source)
Hot side (sink)
Up to date

Operating envelope

-15 °C-10 °C-5 °C0 °C5 °C10 °C15 °C20 °C20 °C30 °C40 °C50 °C60 °C70 °CTe – evaporating temperatureTc – condensing temperatureCOP 2COP 3COP 4COP 5COP 61COP 2.79 · 114 kW

Operating points

Columns
Inputs
Results
Remembered in this browser.
PointSource in → outSink in → outLoadTe / TcHeating capacityElectrical inputCOP heatingActions
110.0 → 7.0 °C40.0 → 45.0 °C100 %4.0 / 48.0 °C114 kW41 kW2.79
Indicative values. Engineering review required.

The EMB 2295-1-4 is a scroll-compressor heat pump on R1234ze (safety class A2L). It delivers 114 kW of heat at 1 °C → -3 °C ethanol 26% on the source side and 47 °C → 53 °C water on the sink side. Catalogue maximum condenser outlet: 65 °C (not verified by this datasheet).

Need an A1 refrigerant? The EMB 2295-1-7 is the R515B variant. Both share one datasheet performance table, which shows no performance advantage for either. Confirm site and safety requirements with engineering.

Rating conditions

2 rated points · datasheet V3.1

Rated points from datasheet V3.1 (2026-06-04). These are rating conditions, not operating limits.

Rating conditions
Mode / configurationSource fluid in → outSink fluid in → outSpeed / load pointCapacityElectrical input / boundaryCOPDatasheet revision
Heating
Standard
ethanol 26%
1 °C → -3 °C
water
47 °C → 53 °C
Not stated114 kW41.5 kW
Compressors only
2.79V3.1
2026-06-04
Cooling
Standard
ethanol 26%
15 °C → 10 °C
water
37 °C → 43 °C
Not stated144 kW34.5 kW
Compressors only
4.18V3.1
2026-06-04

Source is the evaporator side and sink the condenser side, in both modes. Electrical input is compressor power at the rated point, not the value for sizing the supply. The datasheet names no test standard and no simultaneous heating-and-cooling rating.